Switch ? Sensor » General Pneumatic - Self-contained Type
3-Screen Display High-Precision Digital Pressure Switch
ZSE20□(F)/ISE20□
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)IO-Link Devices ? Pressure Switches
Industrial Device Communication Equipment/Wireless System ? Industrial Device Communication Equipment: IO-Link Compatible Products
-
?Visualization of settings
?Simple 3-step setting
?Easy screen switching
It is possible to change the settings while checking the measured value.
?Delay time:1.5 ms or less
?Current consumption: 25 mA or less
?IO-Link compatible
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Output type | Type | Rated pressure range | Enclosure | Applicable fluid |
---|---|---|---|---|---|
ZSE20(F) ISE20 | 1 output | Compound pressure Vacuum pressure Positive pressure | ?100.0 to 100.0 kPa 0.0 to ?101.0 kPa ?0.100 to 1.000 MPa | IP40 | Air |
ZSE20A(F) ISE20A | 2 outputs Analog output (Voltage/Current) | Compound pressure Vacuum pressure Positive pressure | ?100.0 to 100.0 kPa 0.0 to ?101.0 kPa ?0.100 to 1.000 MPa | IP40 | Air |
ZSE20AF-X576 to 580 (Made to Order) | 2 outputs Analog output (Voltage/Current) | Compound pressure | ?500 to 500Pa ?1.000 to 1.000kPa ?2.00 to 2.00kPa ?5.00 to 5.00kPa ?10.00 to 10.00kPa | IP40 | Air |
ZSE20B(F)-(L) ISE20B-(L) | 2 outputs Analog output (Voltage/Current) IO-Link/Switch: 1 output | Compound pressure Vacuum pressure Positive pressure | ?100.0 to 100.0 kPa 0.0 to ?101.0 kPa ?0.100 to 1.000 MPa | IP65 | Air |
ZSE20C(F)-(L) ISE20C(H)-(L) | 2 outputs Analog output (Voltage/Current) IO-Link/Switch: 1 output | Compound pressure Vacuum pressure Positive pressure | ?100.0 to 100.0 kPa 0.0 to ?101.0 kPa ?0.100 to 1.000 MPa ?0.100 to 2.000 MPa | IP65 | General fluids |
2-Color Display High-Precision Digital Pressure Switch ZSE30A(F)/ISE30A
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)-
?With one-touch fitting (Straight, Elbow)
?Space-saving, capable of vertical and horizontal contact mounting
?With display calibration function
?Simultaneous copying is possible for maximum 10 units.
∗ The ZSE30A(F)/ISE30A series now features 2 new models:
the ZSE20(F)/ISE20 and the ZSE20A(F)/ISE20A.
?Click here
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Rated pressure range |
---|---|---|
ZSE30AF | Compound pressure | -100.0 to 100.0kPa |
ZSE30A | Vacuum pressure | 0.0 to -101.0kPa |
ISE30A | Positive pressure | -0.100 to 1.000MPa |
Compact Digital Pressure Switch ZSE10(F)/ISE10
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)-
?Low profile 9.8 mm
?Vertical mounting space reduced to approx. 1/2
(Compared to ZSE/ISE30A series)
?Simultaneous copying is possible for maximum 10 units.
?3-step setting
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Rated pressure range |
---|---|---|
ZSE10F | Compound pressure | -100.0 to 100 kPa |
ZSE10 | Vacuum pressure | 0.0 to -101.0 kPa |
ISE10 | Positive pressure | -0.100 to 1.000 MPa |
2-Color Display Digital Pressure Switch ISE70/75(H)
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)-
?Metal body type (Aluminum die-casted)
?IP67
?With M12 connector
∗ The ISE70 series was discontinued in April 2018.
Please select the ISE70-□-L2 series.
∗ The ISE75 series was discontinued in July 2018.
Please select the ISE77G series.
∗ The ISE75H series was discontinued in December 2022.
Please select the ISE78G series.
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Rated pressure range |
---|---|---|
ISE70 | Positive pressure (For air) | 0 to 1MPa |
ISE75 | Positive pressure (For general purpose fluids) | 0 to 10MPa |
ISE75H | Positive pressure (For general purpose fluids) | 0 to 15MPa |
Compact Pressure Switch ZSE1/ISE1
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Set pressure range |
---|---|---|
ZSE1 | Vacuum pressure | 0 to -101 kPa |
ISE1L | Positive pressure | 0 to 100 kPa |
ISE1 | Positive pressure | 0 to 1 MPa |
Compact Pressure Switch ZSE2/ISE2
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)-
?Can be integrated with a ZX or ZR ejector system
?Comes equipped with a suction filter as standard
? The ZSE2-0X series was discontinued in May 2024.
Please select the ZSE10 series.
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Set pressure range |
---|---|---|
ZSE2 | Vacuum pressure | 0 to -101 kPa |
ISE2L | Positive pressure | 0 to 100 kPa |
ISE2 | Positive pressure | 0 to 1 MPa |
Air Checker/Electronic Pressure Switch PS1000/1100/1200
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)-
?Plug-in port for One-touch fittings.
?With LED light.
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Set pressure range |
---|---|---|
PS1000 | Positive pressure | -0.1 to 0.45 MPa |
PS1100 | For vacuum/residual pressure | -0.1 to 0.4 MPa |
PS1200 | For vacuum | -100 to 0 kPa |
Digital Pressure Switch (Built-in Regulator Type) ISE35
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)-
?Modular type mountable
?ARM10/11 series mountable
?Selectable pressure unit
?With anti-chattering function
?Power-saving mode
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Rated pressure range |
---|---|---|
ISE35 | Positive pressure | -0.1 to 1 MPa |
Pressure Switch/Reed Switch Type IS10
Switches/Sensors/Controller ? Mechanical Pressure Switches-
?16% lighter, 11% smaller (Compared with the IS1000)
?Service life: 5 million cycles
?Can be connected to modular type F.R.L. units
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Set pressure range |
---|---|---|
IS10 | Positive pressure | 0.1 to 0.4 MPa 0.1 to 0.6 MPa |
Pressure Switch/Micro Switch Type IS3000
Switches/Sensors/Controller ? Mechanical Pressure Switches-
?Can be used for micro load, around 10 mA e.g.
?With neon light.
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Set pressure range |
---|---|---|
IS3000 | Positive pressure | 0.1 to 0.7 MPa |
Vacuum Switch/Reed Switch Type ZSM1
Switches/Sensors/Controller ? Mechanical Pressure Switches
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Set pressure range |
---|---|---|
ZSM1 | Vacuum pressure | -27 to -80 kPa |
3-Screen Display High-Precision Digital Pressure Switch
ISE7□/7□G/79S
Switches/Sensors/Controller ? Electronic Pressure Switches/Sensors (Self-contained Type)IO-Link Devices ? Pressure Switches
Industrial Device Communication Equipment/Wireless System ? Industrial Device Communication Equipment: IO-Link Compatible Products
-
?It is possible to change the settings while checking the measured value.
?IO-Link
?Angled display
Good visibility from various mounting positions
?Rotating display
Display can rotate 336 degrees after installation
?Applicable fluid:Air, Non-corrosive gas, Non-flammable gas (ISE70/71)
:Liquid or gas that will not corrode materials of parts
in contact with fluid (ISE7□G/79S)
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Rated pressure range |
---|---|---|
ISE70 | Positive pressure (For air) | 0 to 1MPa |
ISE71 | Positive pressure (For air) | 0 to 1.6MPa |
ISE70G | Positive pressure (For general fluids) | 0 to 1MPa |
ISE75G | Positive pressure (For general fluids) | 0 to 2MPa |
ISE76G | Positive pressure (For general fluids) | 0 to 5MPa |
ISE77G | Positive pressure (For general fluids) | 0 to 10MPa |
ISE78G | Positive pressure (For general fluids) | 0 to 16MPa |
ISE79S | Positive pressure (For general fluids) | 0 to 50MPa |