国产精品永久免费高清,中文字幕亚洲一区二区视频,不卡中文字幕一二三区,九九热在线视频只有精品

WEB Catalog

Product Information ?  WEB Catalog  ? Fluoropolymer Equipment/PVC Equipment  ? High Purity Chemical Liquid Valves

High Purity Chemical Liquid Valves

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

High Purity Chemical Liquid Valve/Air Operated, Integrated Fitting Type LVC

    ?Body material: New PFA
    ?N.C./N.O./Double acting all feature the same configuration.
    ?Compatible with fluid temperatures of 100℃
    ?Manifold type no.: LLC2, LLC3, LLC4, LLC5
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesTypeValve typeApplicable tubing O.D.Orifice diameter (mm?)
LVCAir Operated
Integrated fitting
N.C./N.O./
Double acting
Metric: 3 to 25
Inch: 1/8 to 1
4 to 22

High Purity Chemical Liquid Valve/Air Operated, Threaded Type LVA

    ?Body materials: New PFA/Stainless steel/PPS
    ?Diaphragm materials: PTFE, EPR, or NBR can be selected.
    ?Organic solvents compatible
     Body: Stainless steel, Actuator section: ADC, Buffer: Choose from FKM/EPDM
    ?Manifold type no.: LLA2,LLA3,LLA4,LLA5
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesTypeValve typePort size
Applicable tubing O.D.
Orifice diameter
(mm?)
LVAAir operated
Threaded type
N.C./N.O./
Double acting
1/8 to 12 to 22
LVAAir operated
Organic solvents
compatible
N.C./N.O./
Double acting
Metric: 6 to 19
Inch: 1/4 to 1
4 to 22

High Purity Chemical Liquid Valve/Manually Operated (Integrated Fitting Type/Threaded Type) LVH

    ?Body materials: New PFA/Stainless steel/PPS
    ?Compatible with locking and non-locking types
    ?Organic solvents compatible
     Body: Stainless steel, Actuator section: ADC, Buffer: Choose from FKM/EPDM
    ?Manifold type no.: LLH2,LLH3,LLH4
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesTypeValve typePort size
Applicable tubing O.D.
Orifice diameter
(mm?)
LVHManually operated
(Integrated fitting/Threaded type)
N.C.Threaded type: 1/8 to 1/2
Integrated fitting: Metric: ?3 to ?12
Inch: 1/8 to 1/2
4 to 12
LVHManually operated
Organic solvents
compatible
N.C.Metric: 6 to 19
Inch: 1/4 to 1
4 to 22

Compact Type High Purity Air Operated Chemical Liquid Valve LVD

    ?Space saving, compact model is available.
     Dimension across inlet/outlet ports: Reduced by up to 29%
    ?Body material: New PFA
    ?Diaphragm material: PTFE
    ?Actuator materials: PPS, PVDF (LVD-F/FN)

    Note) Tubing O.D. for the tube extension type
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesTypeValve typeApplicable tubing O.D.
Note)
Metric size
Applicable tubing O.D.
Note)
Inch size
Orifice diameter
(mm?)
LVDIntegrated fittingsN.C./N.O./
Double acting
3 to 191/8 to 3/42 to 16
LVDTube extensionsN.C./N.O./
Double acting
6 to 191/4 to 3/44 to 16
LVD-F/FNLQ1 Integrated fittingsN.C./N.O./
Double acting
3 to 251/8 to 14 to 22
LVD-F/FNLQ3 Integrated fittingsN.C./N.O./
Double acting
6 to 251/4 to 14 to 22
LVD-F/FNTube extensionsN.C./N.O./
Double acting
6 to 251/4 to 14 to 22

High Purity Chemical Liquid Valve/Air Operated, Non-Metallic Exterior LVQ

    ?Screwless construction, Non-metallic construction doesn't use metal
     screws to secure the body of the actuator
    ?Body material: New PFA
    ?Diaphragm material: PTFE
    ?Actuator material: PVDF

    Note) Tubing size

    * The LQ2 insert/integrated fitting type space-saving fitting for
     the LVQ series high-purity chemical liquid valve is to be
     discontinued as of March 2025. Select the LQ1 fitting instead.
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • High Purity Chemical Liquid Valve/Air Operated, Non-Metallic Exterior LVQ
    Manual
    Series Type View search result
    LVQIntegrated fittingView search result
    LVQSpace saving typeView search result
    LVQTube extensionView search result
SeriesTypeValve typeApplicable tubing O.D.
Metric size
Applicable tubing O.D.
Inch size
Orifice diameter
(mm?)
LVQIntegrated fittingN.C./N.O./
Double acting
3 to 251/8 to 14 to 22
LVQSpace saving typeN.C./N.O./
Double acting
Fitting size:
2 to 6
Fitting size:
2 to 6
4 to 22
LVQTube extensionN.C./N.O./
Double acting
6 to 25 Note)1/4 to 1 Note)4 to 22

Go Top

淄博市| 团风县| 天津市| 繁昌县| 祁连县| 望奎县| 响水县| 岑巩县| 长沙县| 玛纳斯县| 琼结县| 靖边县| 滕州市| 萍乡市| 申扎县| 黄大仙区| 福鼎市| 长海县| 鄄城县| 吉木萨尔县| 于都县| 龙泉市| 鄂伦春自治旗| 汶川县| 巨野县| 尼木县| 赣州市| 富裕县| 乐业县| 云阳县| 平凉市| 大渡口区| 项城市| 嘉义县| 伊宁市| 治县。| 宜都市| 滦南县| 富锦市| 将乐县| 聂拉木县|