国产精品永久免费高清,中文字幕亚洲一区二区视频,不卡中文字幕一二三区,九九热在线视频只有精品

WEB Catalog

Product Information ?  WEB Catalog  ? Industrial Device Communication Equipment/Wireless System  ? Industrial Device Communication Equipment: IO-Link Compatible Products

Industrial Device Communication Equipment: IO-Link Compatible Products

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Serial Transmission System EX260

    For Output

    ?The applicable protocols differ depending on the series.
     For details, refer to the catalog of each series.

    ?IP67
    ?RJ45 communication connectors (X205)

     ?Related Products
     ?IO-Link Master
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Serial Transmission System EX260
    Manual
    Series View search result
    EX260View search result
  • Serial Transmission System EX260
    DoC
    Series View search result
    EX260View search result
SeriesEnclosureCommunication protocol?Applicable valve
EX260IP67DeviceNet?
PROFIBUS DP
CC-Link
EtherCAT
PROFINET
EtherNet/IP?
Ethernet POWERLINK
IO-Link (Only available for SY, JSY, VQC communication connectors)
PROFIsafe (Only available for SY, JSY, VQC communication connectors)
SY3000,5000,7000 (Plug-in)
JSY1000,3000,5000 (Plug-in)
VQC1000,2000,4000,5000
SV1000,2000,3000
S0700(IP40)

IO-Link Master EX600-GILB-X60

    ?IO-Link version V1.1
    ?Process data length 32-byte input/32-byte output (per port)
    ?IO-Link port type Class A

     ?IO-Link Devices
SeriesNumber of portsPLC communication protocol
EX600-GILB-X604 portsCC-Link IE Field

Serial Transmission System EX600

    For Input/Output

    ?The applicable protocols differ depending on the series.
     For details, refer to the catalog of each series.

     ?IO-Link Devices

    ? The EX600-SPN1/SPN2 series will be discontinued in October 2023.
     Please select the EX600-SPN3/SPN4 series.
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Serial Transmission System EX600
    Manual
    Series View search result
    EX600View search result
  • Serial Transmission System EX600
    DoC
    Series View search result
    EX600View search result
SeriesEnclosureCommunication protocol?Applicable valve
EX600IP67PROFIBUS DP
DeviceNet?
CC-Link
EtherNet/IP?
EtherNet/IP? (IO-Link unit compatible)
EtherCAT
EtherCAT (IO-Link unit compatible)
PROFINET
PROFINET (IO-Link unit compatible)
MRP (PROFINET) (Made to order)
Ethernet POWERLINK (Made to order)
Modbus TCP (Made to order)
CC-Link IE Field (Made to order)
EtherNet/IP? (IO-Link master compatible) (Made to order)
SY3000,5000,7000 (Plug-in)
JSY1000, 3000, 5000
SV1000,2000,3000
VQC1000,2000,4000,5000
S0700(IP40)

Wireless System EXW1/EX600-W

    ?Noise resistance
     Uses the 2.4 GHz ISM frequency band
     Frequency hopping: Every 2 ms (Fastest)
    ?Communication cables not required
     Reduced wiring work, space, and cost
     Minimized disconnection risk
    ?Provides communication stability in FA environments
    ?Compact and lightweight (EXW1)
     Volume: Approx. 81% reduction, Weight: Approx. 76% reduction
    ?Modular connection is possible. (EX600-W)

     ?IO-Link Master
SeriesEnclosureCommunication protocolApplicable valve
EXW1IP20/IP67DeviceNet?
CC-Link
EtherNet/IP?
EtherCAT?
PROFINET
OPC UA
JSY1000, 3000, 5000
EX600-WIP67 equivalentEtherNet/IP?
PROFINET
SY3000,5000,7000(Plug-in)
SV1000,2000,3000
S0700(IP40)
VQC1000,2000,4000,5000

Wireless System Compact Remote EX600-W

    ?Applicable to existing wireless systems
    ?Compact, Lightweight
     Area: Approx. 61% reduction? (59.8 cm2 ← 155 cm2)
     Volume: Approx. 86% reduction? (159 cm3 ← 1,139 cm3)
     Weight: Approx. 87% reduction? (130 g ← 965 g)
     ? For the e-CON type
      (Compared with the existing remote, M8 connector/digital 8 inputs specification)
    ?Variations
     e-CON type, Grommet type, IO-Link device compatible

     ?Wireless System Base
     ?IO-Link Devices
SeriesEnclosureCommunication protocolRadio wave type
EX600-We-CON type: IP20
Grommet type: IP67
IO-Link device compatible: IP67
SMC original protocolFrequency Hopping Spread Spectrum (FHSS)

Step Motor Controller JXCL1

    ?IO-Link version V1.1
    ?Process data length 14-byte input/22-byte output
    ?Transmission speed COM3 (230.4 kbps)
    ?Minimum cycle time 2.4 ms
    ?IO-Link port type Class A
    ?Click here for Applicable electric actuators

     ?IO-Link Master
SeriesNumber of axesCompatible motor
JXCL11 axisStep motor (Servo/24 VDC)

Electro-Pneumatic Regulator ITV

    ?Stepless control of air pressure in proportion to electrical signals
    ?Sensitivity: 0.2 kPa (100 kPa specification)
    ?Linearity: ±1% or less (F.S.)
    ?Hysteresis: 0.5% or less (F.S.)
    ?Communication: CC-Link, DeviceNet?, PROFIBUS DP, RS-232C, IO-Link

     ?IO-Link Master
SeriesPort sizeSet pressure (MPa)
ITV0000Built-in One-touch fitting
φ4,φ5/32
0.001 to 0.1
0.001 to 0.5
0.001 to 0.9
ITV10001/8,1/40.005 to 0.1
0.005 to 0.5
0.005 to 0.9
ITV20001/4,3/80.005 to 0.1
0.005 to 0.5
0.005 to 0.9
ITV30001/4,3/8,1/20.005 to 0.1
0.005 to 0.5
0.005 to 0.9

Ionizer / Bar Type IZS51

    ?High speed static neutralization: Fastest time 0.1 s
    ?Space saving: Height 70 mm x Width 28 mm
     Compact and flat body
     Can be mounted in narrow spaces
    ?Supports the IO-Link communication protocol
    ?Low maintenance cartridge
     Concentrating the air (for reducing emitter contamination)
     around the emitter and the assisting air (for ion transfer)
     Reduces dirt on the emitter, compared with the existing model
    ?Valve unit option
     For reduction in air consumption by stopping air purge during stand-by
     mode

     ?IO-Link Devices
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Ionizer / Bar Type IZS51
    Manual
    Series View search result
    IZS51View search result
SeriesIon generation methodOffset voltage
(Ion balance)
Function
IZS51Corona discharge typeWithin ±30 VAuto ion balance
Maintenance detection
High voltage abnormality detection
Ion generation stop input

Separate Controller Ionizer/Bar Type/Nozzle Type IZT40/41/42/43

    ?The controller and high-voltage power supply module can be mounted
     separately.
    ?Space saving: Height 37 mm x Width 30 mm (Bar type)
     Thickness 16 mm x Width 53 mm x Height 32 mm (Nozzle type)
    ?One controller can control a maximum of 4 ionizers.
    ?Potential amplitude: 25 V or less
    ?Rapid static neutralization: Fastest time of 0.1 s
    ?3 types of emitter cartridges
     High speed static neutralization cartridge
     Energy saving static neutralization cartridge
     Energy saving high-efficiency cartridge
    ?Static neutralization is possible even when air is not being supplied.
    ?IO-Link Compatible

     ?IO-Link Devices
SeriesTypeIon generation methodOffset voltage
(Ion balance)
IZT42(-L)
Bar type
Dual AC TypeCorona discharge typeWithin ±30 V
IZT41(-L)
Bar type
AC TypeCorona discharge typeWithin ±30 V
IZT40
Bar type
Standard TypeCorona discharge typeWithin ±30 V
IZT43(-L)
Nozzle type
AC TypeCorona discharge typeWithin ±30 V

3-Screen Display High-Precision Digital Pressure Switch 
ZSE20□(F)/ISE20□

    ?Visualization of settings
    ?Simple 3-step setting
    ?Easy screen switching
     It is possible to change the settings while checking the measured value.
    ?Delay time:1.5 ms or less
    ?Current consumption: 25 mA or less
    ?IO-Link compatible
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • 3-Screen Display High-Precision Digital Pressure Switch 
    ZSE20□(F)/ISE20□
    Manual
    Series Type View search result
    ZSE20(F)
    ISE20
    Compound pressure
    Vacuum pressure
    Positive pressure
    View search result
    ZSE20A(F)
    ISE20A
    Compound pressure
    Vacuum pressure
    Positive pressure
    View search result
    ZSE20AF-X576 to 580
    (Made to Order)
    Compound pressureView search result
    ZSE20B(F)-(L)
    ISE20B-(L)
    Compound pressure
    Vacuum pressure
    Positive pressure
    View search result
    ZSE20C(F)-(L)
    ISE20C(H)-(L)
    Compound pressure
    Vacuum pressure
    Positive pressure
    View search result
  • 3-Screen Display High-Precision Digital Pressure Switch 
    ZSE20□(F)/ISE20□
    DoC
    Series Type View search result
    ZSE20(F)
    ISE20
    Compound pressure
    Vacuum pressure
    Positive pressure
    View search result
    ZSE20A(F)
    ISE20A
    Compound pressure
    Vacuum pressure
    Positive pressure
    View search result
    ZSE20AF-X576 to 580
    (Made to Order)
    Compound pressureView search result
    ZSE20B(F)-(L)
    ISE20B-(L)
    Compound pressure
    Vacuum pressure
    Positive pressure
    View search result
    ZSE20C(F)-(L)
    ISE20C(H)-(L)
    Compound pressure
    Vacuum pressure
    Positive pressure
    View search result
SeriesOutput typeTypeRated pressure rangeEnclosureApplicable fluid
ZSE20(F)
ISE20
1 outputCompound pressure
Vacuum pressure
Positive pressure
?100.0 to 100.0 kPa
0.0 to ?101.0 kPa
?0.100 to 1.000 MPa
IP40Air
ZSE20A(F)
ISE20A
2 outputs
Analog output
(Voltage/Current)
Compound pressure
Vacuum pressure
Positive pressure
?100.0 to 100.0 kPa
0.0 to ?101.0 kPa
?0.100 to 1.000 MPa
IP40Air
ZSE20AF-X576 to 580
(Made to Order)
2 outputs
Analog output
(Voltage/Current)
Compound pressure?500 to 500Pa
?1.000 to 1.000kPa
?2.00 to 2.00kPa
?5.00 to 5.00kPa
?10.00 to 10.00kPa
IP40Air
ZSE20B(F)-(L)
ISE20B-(L)
2 outputs
Analog output
(Voltage/Current)
IO-Link/Switch: 1 output
Compound pressure
Vacuum pressure
Positive pressure
?100.0 to 100.0 kPa
0.0 to ?101.0 kPa
?0.100 to 1.000 MPa
IP65Air
ZSE20C(F)-(L)
ISE20C(H)-(L)
2 outputs
Analog output
(Voltage/Current)
IO-Link/Switch: 1 output
Compound pressure
Vacuum pressure
Positive pressure
?100.0 to 100.0 kPa
0.0 to ?101.0 kPa
?0.100 to 1.000 MPa
?0.100 to 2.000 MPa
IP65General fluids

3-Screen Display High-Precision Digital Pressure Switch 
ISE7□/7□G/79S

    ?It is possible to change the settings while checking the measured value.
    ?IO-Link
    ?Angled display
     Good visibility from various mounting positions
    ?Rotating display
     Display can rotate 336 degrees after installation
    ?Applicable fluid:Air, Non-corrosive gas, Non-flammable gas (ISE70/71)
             :Liquid or gas that will not corrode materials of parts
              in contact with fluid (ISE7□G/79S)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • 3-Screen Display High-Precision Digital Pressure Switch 
    ISE7□/7□G/79S
    Manual
    Series Type View search result
    ISE70Positive pressure (For air)View search result
    ISE71Positive pressure (For air)View search result
    ISE70GPositive pressure (For general fluids)View search result
    ISE75GPositive pressure (For general fluids)View search result
    ISE76GPositive pressure (For general fluids)View search result
    ISE77GPositive pressure (For general fluids)View search result
    ISE78GPositive pressure (For general fluids)View search result
    ISE79SPositive pressure (For general fluids)View search result
  • 3-Screen Display High-Precision Digital Pressure Switch 
    ISE7□/7□G/79S
    DoC
    Series Type View search result
    ISE70Positive pressure (For air)View search result
    ISE71Positive pressure (For air)View search result
    ISE70GPositive pressure (For general fluids)
    ISE75GPositive pressure (For general fluids)
    ISE76GPositive pressure (For general fluids)
    ISE77GPositive pressure (For general fluids)
    ISE78GPositive pressure (For general fluids)
    ISE79SPositive pressure (For general fluids)
SeriesTypeRated pressure range
ISE70Positive pressure (For air)0 to 1MPa
ISE71Positive pressure (For air)0 to 1.6MPa
ISE70GPositive pressure (For general fluids)0 to 1MPa
ISE75GPositive pressure (For general fluids)0 to 2MPa
ISE76GPositive pressure (For general fluids)0 to 5MPa
ISE77GPositive pressure (For general fluids)0 to 10MPa
ISE78GPositive pressure (For general fluids)0 to 16MPa
ISE79SPositive pressure (For general fluids)0 to 50MPa

3-Screen Display Digital Gap Checker/IO-Link Compatible ISA3-L

    ?Monitoring the placement condition of the workpiece Indicates failure/abnormality
    ?Double sensor providing improved preventive and predictive maintenance (IoT) based on IO-Link
     Process data provides Displayed value, Outlet pressure, and Supply pressure value.
    ?NPN/PNP switch function
    ?3-screen display (Setting)
    ?Window comparator type
    ?Zero cut-off range can be changed.

     ?IO-Link Master
SeriesRated distance rangePiping specifications: Supply sidePiping specifications: Detection side
ISA3-F□L0.01 to 0.03 mmRc, G 1/8φ4, φ6 One-touch fitting, G 1/8
ISA3-G□L0.02 to 0.15 mmRc, G 1/8φ4, φ6 One-touch fitting, G 1/8
ISA3-H□L0.05 to 0.30 mmRc, G 1/8φ4, φ6 One-touch fitting, G 1/8

3-Screen Display Multi-channel Digital Sensor Monitor PSE200A

    ?Up to 4 pressure sensors can be connected!
     Centralized control saves installation space.
     A single monitor various applications
    ?It is possible to change the settings while checking the measured value.
    ?IO-Link compatible

     ?IO-Link Master
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • 3-Screen Display Multi-channel Digital Sensor Monitor PSE200A
    Manual
    Series View search result
    PSE200AView search result
  • 3-Screen Display Multi-channel Digital Sensor Monitor PSE200A
    DoC
    Series View search result
    PSE200AView search result
SeriesSet pressure rangeApplicable pressure sensors
PSE200A?0.2 to 2.1 kPa
10 to ?105 kPa
?105 to 105 kPa
?10 to 105 kPa
?50 to 525 kPa
?0.105 to 1.05 MPa
?0.105 to 2.1 MPa
?0.25 to 5.25 MPa
?0.5 to 10.5 MPa
PSE550
PSE531/PSE541/PSE561
PSE533/PSE543/PSE563/PSE573
PSE532
PSE564/PSE574
PSE530/PSE540/PSE560/PSE570
PSE575
PSE576
PSE577

3-Color Display Digital Flow Switch PF2MC7□(-L)

    ?Dry air, N2
    ?3-color/3-screen display
    ?A wide range of flow measurement is possible with 1 product.
     Flow ratio 100:1, Smallest settable increment: 1 L/min
    ?Grease-free
    ?IO-Link compatible

     ?IO-Link Master
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • 3-Color Display Digital Flow Switch PF2MC7□(-L)
    Manual
    Series View search result
    PF2MCView search result
SeriesRated flow range (L/min)
PF2MC5 to 500
10 to 1000
20 to 2000

2-Color Display Digital Flow Switch PF2M7(-L)

    ?3-Screen Display Digital Flow Monitor (Dedicated for the PF2M7) [New]
     Allows for the monitoring of remote lines PFGM302 Series
    ?Dry air, N2, Ar, CO2
    ?A wide range of flow measurement is possible with 1 product.
     Flow ratio: 100:1, Smallest settable increment: 0.01 L/min
    ?Improved resistance to moisture and foreign matter
    ?Compact, Lightweight
     Weight: 27.3% lighter (55 g → 40 g)
    ?Low current consumption: 35 mA or less
    ?Grease-free
    ?IO-Link compatible

     ?IO-Link Master
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • 2-Color Display Digital Flow Switch PF2M7(-L)
    Manual
    Series View search result
    PF2M7View search result
  • 2-Color Display Digital Flow Switch PF2M7(-L)
    DoC
    Series View search result
    PF2M7View search result
SeriesRated flow range (L/min)
PF2M70.01 to 1 (0.01 to 0.5)
0.02 to 2 (0.02 to 1)
0.05 to 5 (0.05 to 2.5)
0.1 to 10 (0.1 to 5)
0.3 to 25 (0.3 to 12.5)
0.5 to 50 (0.5 to 25)
1 to 100 (1 to 50)
2 to 200 (2 to 100)
( ): For CO2

3-Color Display Digital Flow Switch for Water PF3W-Z/L

    ?Applicable fluid: Water, Ethylene glycol aqueous solution
    ?Lightweight: Max. 53% reduction (40 L/min, With temperature sensor)
    ?IO-Link compatible
    ?3-color/2-screen display
    ?Compatible with the temperature sensor & flow adjustment valve
    ?Fluid temperature: 0 to 90℃
    ?Compatible with the PFG200 series 3-screen display 4-channel flow
     monitor

     ?IO-Link Master
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • 3-Color Display Digital Flow Switch for Water PF3W-Z/L
    Manual
    Series View search result
    PF3W-ZView search result
    PF3W-L
    (IO-Link compatible)
    View search result
  • 3-Color Display Digital Flow Switch for Water PF3W-Z/L
    DoC
    Series View search result
    PF3W-ZView search result
    PF3W-L
    (IO-Link compatible)
    View search result
SeriesRated flow range (L/min)
PF3W-Z0.5 to 4
2 to 16
5 to 40
10 to 100
PF3W-L
(IO-Link compatible)
0.5 to 4
2 to 16
5 to 40
10 to 100
50 to 250

Digital Flow Switch Manifold for Water PF3WB/C/S/R

    ?Applicable fluid: Water, Ethylene glycol aqueous solution
    ?Space saving
     Footprint Max. 85% reduction
     Weight Max. 65% reduction
    ?Needs no piping: Work-hour for installation reduced by up to 45%
    ?IO-Link compatible
    ?3-color/2-screen display
    ?Fluid temperature: 0 to 90℃

     ?IO-Link Master
SeriesRated flow range (L/min)
PF3WB
Integrated type (Basic type)
0.5 to 4
2 to 16
5 to 40
PF3WC
Integrated type (Straight type)
0.5 to 4
2 to 16
5 to 40
PF3WS
Remote type (Supply type)
0.5 to 4
2 to 16
5 to 40
PF3WR
Remote type (Return type)
0.5 to 4
2 to 16
5 to 40

3-Color Display Digital Flow Switch for Large Flow PF3A□H(-L)

    ?Applicable fluid: Air, N2
    ?Flow range: Max. 12000 L/min
    ?Flow ratio 100:1
     A wide range of flow measurement is possible with 1 product.
    ?Improved drainage and resistance to foreign matter
    ?Pressure loss: 75% reduction (20 kPa → 5 kPa)
    ?Through bore construction
    ?IO-Link compatible
    ?Can be connected to the air combination (Modular type)
    ?A 4-screen display digital flow switch with pressure/temperature sensor
     (modular type) is available.
     Simultaneous measurement of the (accumulated) flow rate, pressure, and temperature is possible.

     ?IO-Link Master
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • 3-Color Display Digital Flow Switch for Large Flow PF3A□H(-L)
    Manual
    Series View search result
    PF3A7□HView search result
  • 3-Color Display Digital Flow Switch for Large Flow PF3A□H(-L)
    DoC
    Series View search result
    PF3A7□HView search result
SeriesRated flow range (L/min)
PF3A7□H10 to 1000
20 to 2000
30 to 3000
60 to 6000
120 to 12000

Digital Flow Switch for Water PF3W7□-X445

    ?IO-Link version V1.1
    ?Process data length 6-byte input
    ?Transmission speed COM2 (38.4 kbps)
    ?Minimum cycle time 3.5 ms
    ?IO-Link port type Class A

     ?IO-Link Master
SeriesApplicable fluidRated flow range
PF3W704-X445Water0.5 to 4 L/min
PF3W720-X445Water2 to 16 L/min
PF3W740-X445Water5 to 40 L/min

Actuator Position Sensor D-MP□

    ?Actuator stroke position is output with an analog signal.
    ?Repeatability: 0.1 mm
    ?Analog output
    ?4 measurement ranges
    ?Switch output
    ?IO-Link compatible
SeriesMeasuring range
D-MP02525 mm±1 mm
D-MP05050 mm±1 mm
D-MP100100 mm±1 mm
D-MP200200 mm±1 mm

Vacuum Manifold for Fieldbus System ZKJ

    ?Vacuum pads and actuator driving can be controlled with a single
     manifold [New]
     ?Positive pressure unit [New]
      5-port solenoid valve
     ?Vacuum unit
      Energy saving ejector Air consumption: 92% reduction
    ?Fieldbus compatible
     Space saving: Requires no separate input/output units
     Reduced wiring time
     Compatible protocols: PROFINET, IO-Link, EtherNet/IP, EtherCAT
    ?Exhaust sealing function
     Quick workpiece release
    ?4 stations/8 stations/12 stations/16 stations manifold compatible
Ejector seriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
ZKJ070.73126
ZKJ101.05348
ZKJ121.26368
ZKJ151.574102

64-station Compatible Manifold Plug-in Compact 5-Port Solenoid Valve JSY3000-L

    ?Valve stations/Number of outputs: For 4 to 64 stations? /128 points
     ? Stations are only available in multiples of 4.
    ?Space saving, Reduced number of SI units, Reduced wiring and wiring
     work
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • 64-station Compatible Manifold Plug-in Compact 5-Port Solenoid Valve JSY3000-L
    Manual
    Series View search result
    JSY3000-LView search result
  • 64-station Compatible Manifold Plug-in Compact 5-Port Solenoid Valve JSY3000-L
    Manifold
    Series View search result
    JSY3000-LView search result
SeriesFlow rate characteristics
4/2 → 3/5 (A/B → E)
C [dm3/(s·bar)]
Flow rate characteristics
4/2 → 3/5 (A/B → E)
b
Applicable
cylinder size
Power consumption
(W)
JSY3000-L2.770.27φ500.4 (Standard)
0.1 (With power-saving circuit)

IO-Link Compatible 2 in 1 Auto Switch D-MH2□

    ?Outputs process data according to the actuator stroke position
    ?A single switch can discriminate between max. 3 position points.
    ?Discriminable resolution: ±0.1 mm ? Within the high-resolution range
    ?Detection position setting can be done away from the actuator.
    ?Process data output (–1000 to 1000)
     Can also be used with the 2 in 1 auto switch single unit if there is
     an IO-Link master
  • IO-Link Compatible 2 in 1 Auto Switch D-MH2□
    Manual
    Series Type View search result
    D-MH2□IO-Link compatible
    2 in 1 auto switch
    View search result
  • IO-Link Compatible 2 in 1 Auto Switch D-MH2□
    DoC
    Series Type View search result
    D-MH2□IO-Link compatible
    2 in 1 auto switch
    View search result
SeriesTypeNumber of set pointsOutput type
D-MH2□IO-Link compatible
2 in 1 auto switch
2 points
3 points
NPN output
PNP output

Valve Manifold Integrated with Ejector System JSY1000-E

    ?Spacer type ejector with additional high-noise reduction silencer [New]
    ?A vacuum release flow adjustment unit has been added.
    ?Compact all-in-one manifold
     The devices have been integrated into one for applications in which an
     actuator and vacuum suction are used together.
    ?EtherCAT?,IO-Link [New],PROFINET? [New] compatible
    ?Wiring/piping saving through use of all-in-one manifold
    ?Installation area: 64% reduction
    ?Weight: 42% reduction
    ?Energy saving function
     CO2 emissions (Air consumption): 90% reduction

     ?IO-Link Master
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Valve Manifold Integrated with Ejector System JSY1000-E
    Manual
    Series View search result
    JSY1000-EView search result
  • Valve Manifold Integrated with Ejector System JSY1000-E
    Manifold
    Series View search result
    JSY1000-EView search result
SeriesFlow rate characteristics
4/2→3/5 (A/B→E)
C [dm3/(s?bar)]
Flow rate characteristics
4/2→3/5 (A/B→E)
b
Applicable
cylinder size
Power
consumption
(W)
JSY1000-E0.910.48φ400.2
(With power-saving circuit)

Go Top