国产精品永久免费高清,中文字幕亚洲一区二区视频,不卡中文字幕一二三区,九九热在线视频只有精品

WEB Catalog

Product Information ?  WEB Catalog  ? Industrial Device Communication Equipment/Wireless System  ? Other: RS485 Compatible Products

Other: RS485 Compatible Products

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Thermo-chiller/Standard Type HRS

    ?With this chiller, cooling water can be obtained anywhere it is necessary because of easy installation and easy operation.
    ?For a wide range of applications, such as laser machine tools, analytical equipment,
     LCD manufacturing equipment, mold temperature control, etc.
    ?Compact: W 377 x H 615 x D 500 mm, 40 kg (HRS012/018/024)
    ?Timer function, Low liquid level protection, Power failure auto-restart,
     Anti-freezing function, etc.
    ?Self diagnosis function
    ?Ideal for overseas models (Single-phase 200 to 230 VAC, Single-phase 100, 115 VAC)
    ?Compliant with UL Standards, CE-marking
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/Standard Type HRS
    Manual
    Series View search result
    HRS012 to 060View search result
  • Thermo-chiller/Standard Type HRS
    DoC
    Series View search result
    HRS012 to 060View search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRS012 to 0605 to 40℃1.3 kW
1.9 kW
2.4 kW
3.2 kW
4.2 kW
5.1 kW
5.9 kW
(60 Hz)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
Deionized water
Ethylene glycol aqueous solution (15%)

Thermo-chiller/Environmentally Resistant Type HRS-R

    ?Resistant to dust and water splashing
    ?Protection of the electrical unit: IP54
    ?Metal panel
     The entire exterior surface is metal.
     A stainless steel panel can be selected. (Option)
    ?A large capacity tank (12 L) is available. (Option)
    ?Ambient temperature: 5 to 45°C
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/Environmentally Resistant Type HRS-R
    Manual
    Series View search result
    HRS-RView search result
  • Thermo-chiller/Environmentally Resistant Type HRS-R
    DoC
    Series View search result
    HRS-RView search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRS-R5 to 40℃1.9 kW
2.9 kW
5 kW
(60 Hz)
±0.1℃Air-cooled refrigerationTap water
Ethylene glycol aqueous solution (15%)

Thermo-chiller/Standard Type HRS090

    ?Lightweight and compact
    ?Cooling capacity: 9 kW
    ?Temperature stability: ±0.5°C
    ?Set temperature range: 5 to 35°C
    ?Max. ambient temperature: 45°C
    ?Power supply: 3-phase 200 to 230 VAC, 380 to 415 VAC, 460 to 480VAC
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/Standard Type HRS090
    Manual
    Series View search result
    HRS090View search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRS0905 to 35℃9kW (60Hz)±0.5℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
Deionized water
Ethylene glycol aqueous solution (15%)

Thermo-chiller/Standard Type HRS100/150

    ?No heater is required, as the circulating fluid is heated using only the heat exhausted by the refrigerating circuit.
    ?Compatible with power supplies in Europe, Asia, Oceania, North, Central, and South America
    ?Low-noise design: 70 dB (A)
    ?Outdoor installation: IPX4
    ?Compact, Space saving
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRS100
HRS150
5 to 35℃9.5 kW
14.5 kW
(60 Hz)
±1.0℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
Deionized water
Ethylene glycol aqueous solution (15%)

Thermo-chiller/Standard Type HRS200

    ?3-phase 380 to 415 VAC (50 Hz), 3-phase 460 to 480 VAC (60 Hz)
    ?No heater is required, as the circulating fluid is heated using only the heat exhausted by the refrigerating circuit.
    ?Outdoor installation: IPX4
    ?Compact, Space saving

  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRS2005 to 35℃20.5 kW±1.0℃Air-cooled refrigerationTap water
Deionized water
Ethylene glycol aqueous solution (15%)

Thermo-chiller/Inverter Type HRSH090

    ?Power consumption reduced by 53%
     Complete with energy-saving triple inverter!
    ?Cooling capacity: 9.5 kW (Air-cooled), 11.0 kW (Water-cooled)
    ?Temperature stability: ±0.1°C
    ?Set temperature range: 5°C to 40°C
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/Inverter Type HRSH090
    Manual
    Series View search result
    HRSH090View search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRSH0905 to 40℃9.5 kW±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
Deionized water
Ethylene glycol aqueous solution (15%)

Thermo-chiller/Inverter Type HRSH

    ?Complete with energy-saving triple inverter!
    ?Outdoor installation, Splashproof type (IPX4)
    ?Max. ambient temperature: 45℃
    ?Min. ambient temperature: –20℃ (For the air-cooled type)
    ?Temperature stability: ±0.1℃ (When a load is stable)
    ?Space saving and lightweight: 280 kg (25 kW type)
    ?Compliant with UL Standards, CE-marking
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/Inverter Type HRSH
    Manual
    Series View search result
    HRSHView search result
  • Thermo-chiller/Inverter Type HRSH
    DoC
    Series View search result
    HRSHView search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRSH5 to 35℃10 kW
15 kW
20 kW
25 kW
28 kW
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
Deionized water
Ethylene glycol aqueous solution (15%)

Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRL

    ?Temperatures for 2 fluid channel systems can be controlled individually
     by one chiller.
    ?Space saving, Reduced wiring
     Footprint: 22% reduction
     One power supply system for 2 channels
    ?Energy saving
     Power consumption reduced by 30%
    ?Touch panel
    ?Power supply:
     3-phase 200 VAC (50 Hz)
     3-phase 200 to 230 VAC (60 Hz)
     3-phase 380 to 415 VAC (50/60 Hz)
     3-phase 460 to 480 VAC (60 Hz)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRL
    Manual
    Series View search result
    HRL100
    HRL200
    HRL300
    HRL400
    View search result
  • Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRL
    DoC
    Series View search result
    HRL100
    HRL200
    HRL300
    HRL400
    View search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRL100
HRL200
HRL300
HRL400
CH1: 15 to 25℃
CH2: 20 to 40℃
CH1:9 kw, 19 kW,
26 kW, 37kw
CH2: 1.0 kW (Max. 1.5 kW)
CH1: ±0.1
CH2: ±0.5
Air-cooled
refrigeration
Water-cooled
refrigeration
Tap water,
Deionized water

Thermo-chiller/Rack Mount Type HRR

    ?Operable without the need to remove the unit from the rack
     Front access: Simple to control, service, and maintain with all filters and drainage accessible via the front panel
    ?Space saving: Multiple chillers can be mounted to a 19-inch rack.
    ?Cooling capacity: 1.1/1.2/1.8/2.4/3.0/5.1 kW (60 Hz)
    ?Temperature stability: ±0.1℃
    ?Global power supply:
     Single-phase 100 VAC (50/60 Hz)/115 VAC (60 Hz)
     Single-phase 200 to 230 VAC (50/60 Hz)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/Rack Mount Type HRR
    Manual
    Series View search result
    HRRView search result
  • Thermo-chiller/Rack Mount Type HRR
    DoC
    Series View search result
    HRRView search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRR5 to 35℃
15 to 35℃
1.1 kW
1.2 kW
1.8 kW
2.4 kW
3.0 kW
5.1 kW
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
Ethylene glycol aqueous solution (15%)

EU F-Gas Regulation-compliant Refrigerated Thermo-chiller HRZ-F

    ?More effective energy-saving is achieved through use of a DC inverter compressor and an inverter pump.
    ?Energy saving
     The inverter controls the number of motor rotations of the compressor and pump according to the load from the user’s application.
     Power consumption: Max. 65% reduction
     Facility water: Max. 67% reduction
    ?High performance
     Temperature stability: ±0.1°C (When a load is stable)
     Cooling time: Max. 46% reduction (SMC comparison)
    ?Refrigerant: R410A (HFC)/R448A (HFC/HFO)
  • EU F-Gas Regulation-compliant Refrigerated Thermo-chiller HRZ-F
    Manual
    Series View search result
    HRZ-FView search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling
method
Circulating fluid
HRZ-F-20 to 40℃
10 to 60℃
-20 to 90℃
2 kW, 4 kW, 8 kW, 10 kW±0.1℃Water-cooled
refrigeration
Fluorinated fluids
Ethylene glycol aqueous solution
Tap water/Deionized water

Thermo-chiller/High-performance Type HRZ

This product can only be shipped to China, Taiwan, Korea, Singapore,Malaysia, and Japan. For use in regions other than the aforementioned, order the HRZ-F.

    ?Suitable for semiconductor processing equipment with a wide variety of
     features, such as high-temperature stability, a wide temperature range,
     failure diagnosis, external communication, etc.
    ?Compliant with various safety standards
    ?Compliant with UL Standards, SEMI Standards, CE-marking

  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chiller/High-performance Type HRZ
    Manual
    Series Cooling capacity View search result
    HRZ1 kW, 2 kW,
    4 kW, 8 kW
    View search result
  • Thermo-chiller/High-performance Type HRZ
    DoC
    Series Cooling capacity View search result
    HRZ1 kW, 2 kW,
    4 kW, 8 kW
    View search result
SeriesSet temperature rangeCooling capacityTemperature stabilityCooling methodCirculating fluid
HRZ-20 to 40℃
20 to 90℃
-20 to 90℃
1 kW, 2 kW,
4 kW, 8 kW
±0.1℃Water-cooled refrigerationFluorinated fluids/Ethylene glycol aqueous solution (60%)/Tap water, Deionized water

Non F-Gas (CO2 Refrigerant) Refrigerated Thermo-chiller HRZC

    ?Non F-Gas
    ?Uses a CO2 refrigerant
    ?Greatly reduced GWP
    ?GWP = 1 Compliant with each country’s refrigerant regulations
     EU refrigerant regulations: GWP150 or more
     US refrigerant regulations: GWP700 or more
     California, US refrigerant regulations: GWP750 or more
     ? “GWP” indicates the global warming potential. The values are based on
     the IPCC AR4.
    ?Air transport possible
    ?Eliminates the need to pay for F-Gas recovery & disposal
    ?Eliminates the need for periodic inspections based on the Fluorocarbon
     Emissions Control Act (Japan)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Non F-Gas (CO2 Refrigerant) Refrigerated Thermo-chiller HRZC
    Manual
    Series View search result
    HRZCView search result
  • Non F-Gas (CO2 Refrigerant) Refrigerated Thermo-chiller HRZC
    DoC
    Series View search result
    HRZCView search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling
method
Circulating
fluid
HRZC?20 to 90℃10 kW±0.1℃Water-cooled
refrigeration
Fluorinated fluids
60% ethylene glycol aqueous solution
Deionized water/Tap water

Thermo-chillers for the Semiconductor Industry INR-495-042/INR-495-043

    ?Non F-Gas (CO2 refrigerant)
    ?GWP: 1 (Natural refrigerant)
    ?EU refrigerant regulations: GWP150 or less?
    ?US refrigerant regulations: GWP700 or less?
    ?California, US refrigerant regulations: GWP750 or less
     ?As of December 2023
    ?Air transport possible
     No air transport restrictions for non-toxic and non-flammable?
     refrigerants
     ?A1 (ASHRAE34 standard)
    ?No F-Gas management required
     Eliminates the need for periodic inspections based on the Fluorocarbon
     Emissions Control Act (Japan)
    ?No F-Gas recovery & disposal costs
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Thermo-chillers for the Semiconductor Industry INR-495-042/INR-495-043
    DoC
    Series View search result
    INR-495-042
    INR-495-043
    View search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling
method
Circulating
fluid
INR-495-042
INR-495-043
-20 to 708.5 kW±1.0℃Water-cooled
refrigeration
Fluorinated fluid

Go Top

广河县| 沁阳市| 隆化县| 克拉玛依市| 衡山县| 珲春市| 舞钢市| 郧西县| 南岸区| 文昌市| 日喀则市| 德惠市| 织金县| 怀集县| 青铜峡市| 泾阳县| 渑池县| 通州区| 镇雄县| 广丰县| 兴和县| 青神县| 招远市| 承德县| 洛隆县| 肇庆市| 临漳县| 惠来县| 神农架林区| 尉氏县| 衡山县| 新乐市| 阿坝| 六盘水市| 赤峰市| 嘉荫县| 东丽区| 海晏县| 七台河市| 老河口市| 司法|