Non F-Gas (CO2 Refrigerant) Refrigerated Thermo-chiller HRSC

    · Air transport possible
    · Uses CO2 refrigerant (R744)
    · Greatly reduced GWP
    · Eliminates the need to pay for F-Gas recovery & disposal
    · Eliminates the need for periodic inspections based on the Fluorocarbon Emissions Control Act (Japan)
SeriesSet temperature rangeCooling capacityTemperature stabilityCooling methodCirculating fluid
HRSC012?0605 to 40℃1.3kW to 5.9kW±0.1℃Air-cooled refrigeration, Water-cooled refrigerationTap water, Ethylene glycol aqueous solution (15%)
HRSC0905 to 40℃9.5kW,11kW±0.1℃Air-cooled refrigeration, Water-cooled refrigerationTap water, Ethylene glycol aqueous solution (15%), Deionized water
HRSC1005 to 35℃10.5kW,11.5kW±0.1℃Air-cooled refrigeration, Water-cooled refrigerationTap water, Ethylene glycol aqueous solution (15%), Deionized water

Non F-Gas Uses CO2 Refrigerant (R744) Refrigerated Thermo-chiller HRZC

    ?Non F-Gas
    ?Uses CO2 Refrigerant (R744)
    ?Greatly reduced GWP
    ?GWP = 1 Compliant with each country’s refrigerant regulations
     EU refrigerant regulations: GWP150 or more
     US refrigerant regulations: GWP700 or more
     California, US refrigerant regulations: GWP750 or more
     ? “GWP” indicates the global warming potential. The values are based on
     the IPCC AR4.
    ?Air transport possible
    ?Eliminates the need to pay for F-Gas recovery & disposal
    ?Eliminates the need for periodic inspections based on the Fluorocarbon
     Emissions Control Act (Japan)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Non F-Gas Uses CO2 Refrigerant (R744) Refrigerated Thermo-chiller HRZC
    Manual
    Series View search result
    HRZCView search result
  • Non F-Gas Uses CO2 Refrigerant (R744) Refrigerated Thermo-chiller HRZC
    DoC
    Series View search result
    HRZCView search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling
method
Circulating
fluid
HRZC?20 to 90℃10 kW±0.1℃Water-cooled
refrigeration
Fluorinated fluids
60% ethylene glycol aqueous solution
Deionized water/Tap water

Non F-Gas Uses (CO2 Refrigerant) Thermo-chillers for the Semiconductor Industry INR-495-042/INR-495-043

    ?Non F-Gas (CO2 refrigerant R744)
    ?GWP: 1 (Natural refrigerant)
    ?EU refrigerant regulations: GWP150 or less?
    ?US refrigerant regulations: GWP700 or less?
    ?California, US refrigerant regulations: GWP750 or less
     ?As of December 2023
    ?Air transport possible
     No air transport restrictions for non-toxic and non-flammable?
     refrigerants
     ?A1 (ASHRAE34 standard)
    ?No F-Gas management required
     Eliminates the need for periodic inspections based on the Fluorocarbon
     Emissions Control Act (Japan)
    ?No F-Gas recovery & disposal costs
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Non F-Gas Uses (CO2 Refrigerant) Thermo-chillers for the Semiconductor Industry INR-495-042/INR-495-043
    DoC
    Series View search result
    INR-495-042
    INR-495-043
    View search result
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling
method
Circulating
fluid
INR-495-042
INR-495-043
-20 to 708.5 kW±1.0℃Water-cooled
refrigeration
Fluorinated fluid

[Low GWP Refrigerant Chiller] Thermo-chiller Standard Type HRSF

    ?Low GWP Refrigerant Chiller
     GWP: 146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
     EU refrigerant regulations: GWP150 or more
     US refrigerant regulations: GWP700 or more
     California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?No heater is required, as the circulating fluid is heated using only the heat
     exhausted by the refrigerating circuit.
    ?Compatible with power supplies in Europe, Asia, Oceania, and North,
     Central, and South America
    ?3-phase 400 VAC Low-noise design 70 dB(A)
    ?Outdoor installation IPX4
  • [Low GWP Refrigerant Chiller] Thermo-chiller Standard Type HRSF
    Manual
    Series Cooling capacity View search result
    HRSF012 to 0601.3 kW, 1.9 kW, 2.4 kW,
    3.2 kW, 5.9 kW (60 Hz)
    View search result
SeriesSet temperature
range
Cooling capacityTemperature
stability
Cooling methodCirculating fluid
HRSF012 to 0605 to 40℃1.3 kW, 1.9 kW, 2.4 kW,
3.2 kW, 5.9 kW (60 Hz)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
15 to 40% Ethylene glycol aqueous solution
Deionized water

[Low GWP Refrigerant Chiller] Thermo-chiller Standard Type HRSF150/200

    ?Low GWP Refrigerant Chiller
     GWP: 146?  ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
     EU refrigerant regulations: GWP150 or more
     US refrigerant regulations: GWP700 or more
     California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?No heater is required, as the circulating fluid is heated using only the heat
     exhausted by the refrigerating circuit.
    ?Compatible with power supplies in Europe, Asia, Oceania, and North,
     Central, and South America
    ?3-phase 400 VAC Low-noise design 70 dB(A)
    ?Outdoor installation IPX4
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • [Low GWP Refrigerant Chiller] Thermo-chiller Standard Type HRSF150/200
    Manual
    Series Cooling capacity View search result
    HRSF150
    HRSF200
    15.7kW
    20.5kW (Air-cooled)
    20.6kW (Water-cooled)
    View search result
SeriesSet temperature rangeCooling capacityTemperature
stability
Cooling methodCirculating fluid
HRSF150
HRSF200
5 to 35℃15.7kW
20.5kW (Air-cooled)
20.6kW (Water-cooled)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water
15 to 40% Ethylene glycol aqueous solution
Deionized water

[Low GWP Refrigerant Chiller] Refrigerated Thermo-chiller HRZF

    · Low GWP refrigerant chiller
     GWP:146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
      EU refrigerant regulations: GWP150 or more
      US refrigerant regulations: GWP700 or more
      California, US refrigerant regulations: GWP750 or more
    · Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    · More effective energy-saving is achieved through use of a DC inverter
     compressor and an inverter pump.
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • [Low GWP Refrigerant Chiller] Refrigerated Thermo-chiller HRZF
    Manual
    Series Cooling capacity View search result
    HRZF01010kWView search result
  • [Low GWP Refrigerant Chiller] Refrigerated Thermo-chiller HRZF
    DoC
    Series Cooling capacity View search result
    HRZF01010kWView search result
SeriesSet temperature rangeCooling capacityTemperature stabilityCooling methodCirculating fluid
HRZF010-20?90℃10kW±0.1℃Water-cooled refrigerationFluorinated fluids, 60% ethylene glycol aqueous solution

[Low GWP Refrigerant Chiller] Thermo-chiller/Rack Mount Type HRRF

    ?Low GWP refrigerant chiller
     GWP: 146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
      EU refrigerant regulations: GWP150 or more
      US refrigerant regulations: GWP700 or more
      California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?Operable without the need to remove the unit from the rack
     Front access: Simple to control, service, and maintain with all filters and
     drainage accessible via the front panel
    ?Space saving: Multiple chillers can be mounted to a 19-inch rack.
    ?Cooling capacity: 1.2/1.8 kW (60 Hz)
    ?Temperature stability: ±0.1°C
    ?Power supply: Single-phase 200 to 230 VAC (50/60 Hz)
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesSet temperature rangeCooling capacityTemperature
stability
Cooling methodCirculating fluid
HRRF0125 to 40℃1.0kW/1.2kW
(50/60Hz)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water,
15% ethylene glycol aqueous solution
HRRF0185 to 40℃1.6kW/1.8kW
(50/60Hz)
±0.1℃Air-cooled refrigeration
Water-cooled refrigeration
Tap water,
15% ethylene glycol aqueous solution

[Low GWP Refrigerant Chiller] Thermo-chiller/Dual Channel Thermo-chiller for Lasers HRLF

    ?Low GWP refrigerant chiller
     GWP: 146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
      EU refrigerant regulations: GWP150 or more
      US refrigerant regulations: GWP700 or more
      California, US refrigerant regulations: GWP750 or more
    ?Environmentally friendly R454C as refrigerant (Not available for air
     transport)
    ?Temperatures for 2 fluid channel systems can be controlled individually
     by one chiller.
    ?Space saving, Reduced wiring
    ?Touch panel
     Numeric keypad inputs
     Notice for alarms and maintenance
     Temperature waveform can be displayed.
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
SeriesSet temperature
range
Cooling
capacity
Temperature
stability
Cooling methodCirculating fluid
HRLF200-A-40CH1:5 to 35℃
CH2:10 to 40℃
CH1: 19 kW
CH2: 1.0 kW (Max. 3.0 kW)
CH1: ±0.1℃
CH2: ±0.5℃
Air-cooled refrigerationTap water,
Deionized water
HRLF200-W-40CH1:5 to 35℃
CH2:10 to 40℃
CH1: 21.5 kW
CH2: 1.0 kW (Max. 3.0 kW)
CH1: ±0.1℃
CH2: ±0.5℃
Water-cooled refrigerationTap water,
Deionized water

Go Top

日韩精品一区二区三区十八-日韩人妻少妇一区二区三区| 国产欧美日本不卡精美视频-日本后入视频在线观看| 性激烈欧美三级在线播放-久久中文字幕人妻少妇| 黄片一区二区三区在线看-偷拍一区二区在线观看| 成人av一区二区蜜桃-亚洲色图激情人妻欧美| 亚洲另类熟女国产精品-懂色一区二区三区在线播放| 色噜噜噜噜一区二区三区-欧美最猛黑人做爰视频| 久久精品亚洲国产av久-国产精品视频一区二区免费| av中文字幕男人天堂-懂色av一区二区三区在线观看| 国产日韩电影一区二区三区-美女露双奶头无遮挡物| 日本中文字幕永久在线人妻蜜臀-欧美一区二区的网站在线观看| 黄片一区二区三区在线看-偷拍一区二区在线观看| 在线成色中文综合网站-国产二区精品视频在线观看| 哦啊好大用力欧美视频-麻豆国产传媒片在线观看| 极品人妻av在线播放-久久精品视频一区二区三区| 中文字幕偷拍亚洲九色-亚洲视频不卡一区二区天堂| 国产精品二区高清在线-91精品91久久久久久| 白嫩美女娇喘呻吟高潮-久久一区二区三区日产精品| 国产日韩电影一区二区三区-美女露双奶头无遮挡物| 国产福利视频一区二区三区-日韩人妻中文视频精品| 免费午夜福利在线观看-黄色日本黄色日本韩国黄色| 亚洲av日韩五月天久热精品-国产日韩欧美一区二区三区群战| 欧美mv日韩mv视频-熟妇人妻ⅴa精品中文| 91亚洲美女视频在线-熟妇人妻精品一区二区三区蜜臀| 欧美三级韩国三级日本三斤-日本不卡一区不卡二区| 91大神国内精品免费网站-亚洲免费电影一区二区| 国产av剧情护士麻豆-三级国产精品欧美在线观看| 亚洲区欧美区在线视频-亚洲碰碰人人AV熟女天堂| 久久久国产精品电影片-精品孕妇人妻一区二区三区| 性色国产成人久久久精品二区三区-偷窥中国美女洗澡视频| 亚洲欧美激情自拍色图-国产亚洲精品sese在线播放| 欧美视频在线观看国产专区-亚洲91精品在线观看| 欧美日韩国产综合四区-爆操极品尤物熟妇14p| 亚洲一区二区少妇激情-国产精品美女久久高潮| 一区二区国产高清在线-日本高清无卡一区二区三区| 亚洲av日韩五月天久热精品-国产日韩欧美一区二区三区群战| 亚洲一区精品一区在线观看-日本久久久一区二区三区| 九九热这里只有精品九九-欧美日韩人妻精品一二三| 熟妇勾子乱一区二区三区-欧美爱爱视频一区二区| 亚洲av乱码一区二区-九九免费在线观看视频| 免费av一区在线观看-国产精品视频高潮流白浆视频免费|