国产精品永久免费高清,中文字幕亚洲一区二区视频,不卡中文字幕一二三区,九九热在线视频只有精品

WEB Catalog

Product Information ?  WEB Catalog  ? Vacuum Equipment (Vacuum Generators/Vacuum Suction Cups/Other)  ? Vacuum Ejectors (Vacuum Generators)/Vacuum Pump Systems

Vacuum Ejectors (Vacuum Generators)/Vacuum Pump Systems

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Vacuum Unit (Vacuum Generators) ZK2□A

    ?Supply valve: An N.O. specification has been added.
     Can hold vacuum? even when the power goes out or is turned off
     Prevents the sudden dropping of workpieces?
     ? Supposing the supply pressure is being maintained
    ?An IO-Link compatible pressure switch has been added.
     Allows for ejector control with a single communication line
     Reading of the device information and parameter batch settings are
     possible.
    ?Compatible with ejector systems and vacuum pump systems
    ?Energy saving ejector
     Air supply is cut-off when vacuum is reached.
     Air consumption: 93% reduction (Under SMC’s measurement conditions)
    ?More efficient ejector: Suction flow increased by 50% (Compared to other
     SMC 1-stage ejectors)
    ?Energy saving efficiency: 93% reduction
    ?Improved low noise and suction flow by adoption of a high-noise
     reduction silencer
Ejector seriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
Guidelines for applicable pad
(mm)
Vacuum pump system series
ZK2□070.729242 to 40ZK2□00
ZK2□101.044402 to 50ZK2□00
ZK2□121.261582 to 125ZK2□00
ZK2□151.567902 to 150ZK2□00

Valve Manifold Integrated with Ejector System JSY1000-E

    ?Spacer type ejector with additional high-noise reduction silencer [New]
    ?A vacuum release flow adjustment unit has been added.
    ?Compact all-in-one manifold
     The devices have been integrated into one for applications in which an
     actuator and vacuum suction are used together.
    ?EtherCAT?,IO-Link [New],PROFINET? [New] compatible
    ?Wiring/piping saving through use of all-in-one manifold
    ?Installation area: 64% reduction
    ?Weight: 42% reduction
    ?Energy saving function
     CO2 emissions (Air consumption): 90% reduction

     ?IO-Link Master
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Valve Manifold Integrated with Ejector System JSY1000-E
    Manual
    Series View search result
    JSY1000-EView search result
  • Valve Manifold Integrated with Ejector System JSY1000-E
    Manifold
    Series View search result
    JSY1000-EView search result
SeriesFlow rate characteristics
4/2→3/5 (A/B→E)
C [dm3/(s?bar)]
Flow rate characteristics
4/2→3/5 (A/B→E)
b
Applicable
cylinder size
Power
consumption
(W)
JSY1000-E0.910.48φ400.2
(With power-saving circuit)

Vacuum Manifold for Fieldbus System ZKJ

    ?Vacuum pads and actuator driving can be controlled with a single
     manifold [New]
     ?Positive pressure unit [New]
      5-port solenoid valve
     ?Vacuum unit
      Energy saving ejector Air consumption: 92% reduction
    ?Fieldbus compatible
     Space saving: Requires no separate input/output units
     Reduced wiring time
     Compatible protocols: PROFINET, IO-Link, EtherNet/IP, EtherCAT
    ?Exhaust sealing function
     Quick workpiece release
    ?4 stations/8 stations/12 stations/16 stations manifold compatible
Ejector seriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
ZKJ070.73126
ZKJ101.05348
ZKJ121.26368
ZKJ151.574102

Compact Vacuum Unit ZQ□A

    ?Vacuum pressure switch with energy saving function
     Air consumption: 90% reduction (Based on SMC’s measurement
     conditions)
     Power consumption: 60% reduction [1 W (Existing model) → 0.4 W]
     Vacuum release pressure: From 0 MPa [From 0.3 MPa (Existing model) →
     From 0 MPa]
     Copy function: Reduced setting labor, Minimized risk of setting mistakes
    ?Compatible with ejector systems and vacuum pump systems
    ?IO-Link compatible
Ejector seriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
Guidelines for applicable pad
(mm)
Vacuum pump system series
ZQ050.55152 to 13ZQ000□
ZQ070.710252 to 20ZQ000□
ZQ101.022472 to 32ZQ000□

Large Size Vacuum Module (Vacuum Generators) ZR

    ?Compatible with ejector systems and vacuum pump systems
    ?Necessary functions can be combined through a modular design.
    ?Double solenoids provide a self-holding function.
    ?Adaptable to manifold applications
    ?Functions such as a digital vacuum switch or a solenoid valve can be selected.
SeriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
Guidelines for applicable pad
(mm)
Vacuum pump system series
ZR1101.025532 to 32ZR100
ZR1131.342862 to 50ZR100
ZR1151.5631022 to 100ZR100
ZR1181.8741552 to 125ZR100
ZR1202.0951942 to 150ZR100

Compact Vacuum Unit (Vacuum Generators) ZB

    ?Compatible with ejector systems and vacuum pump systems
    ?Quick response: Response time of the valve 5 ms, vacuum response time
     28 ms
    ?Energy saving: Air consumption reduced by 17%, Vacuum pressure
     reached increased by 21%
    ?Compact/Lightweight: 46 g
    ?With vacuum pressure switch
     Can copy to up to 10 switches simultaneously
    ?IO-Link compatible
Ejector seriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
Guidelines for applicable pad
(mm)
Vacuum pump system series
ZB030.323.52 to 8ZB00
ZB040.43.56.52 to 10ZB00
ZB050.54.5102 to 13ZB00
ZB060.67182 to 20ZB00

Compact Vacuum Ejector (Vacuum Generators) ZA

    ?Total width: 9.9 mm, Total length: 72.9 mm, Total height: 52.5 mm,
     Weight: 50 g
    ?Can be installed on moving parts
    ?Improved response through the shortening of the length of the tube to the pad
    ?Adaptable to manifold applications
  • 2D/3D CAD

    The new SMC CAD SYSTEM, CADENAS, allows you to output 2D/3D CAD data with full part numbers in various data formats. Responses to part number selection has been greatly improved with the newly developed system.

    Click here for 2D/3D CAD
  • Compact Vacuum Ejector (Vacuum Generators) ZA
    Manual
    Series Nozzle diameter
    (mm)
    View search result
    ZA1050.5View search result
    ZA1070.7View search result
SeriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
Guidelines for applicable pad
(mm)
ZA1050.54122 to 13
ZA1070.78282 to 20

Vacuum Ejector (Vacuum Generators) ZM

    ?Valves and switches are unitized.
    ?Adaptable to manifold applications
    ?Maximum absorption flow rate has been increased by 40%.
    ?Max. vacuum pressure: ?84 kPa
SeriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
Guidelines for applicable pad
(mm)
ZM050.515172 to 16
ZM070.723332 to 25
ZM101.038602 to 32
ZM131.344852 to 40
ZM151.5451102 to 50

Multistage Ejector (With built-in ZSE20A vacuum pressure switch)  ZL1/ZL3/ZL6

    ?An IO-Link compatible vacuum pressure switch has been added. (ZL3,
     ZL6) New
     Allows for ejector control with a single communication line
     Reading of the device information and parameter batch settings are
     possible.
    ?Max. suction flow rate: 3 types available: 100, 300, and 600 L/min (ANR)
    ?Air consumption: 91% reduction (ZL3, ZL6)
     Reduced by the pressure switch for vacuum with energy saving function
     and efficient ejectors
    ?Weight: Max. 60% reduction [ZL112 (Existing model): 450 g → ZL1: 180 g]
SeriesNozzle diameter
(mm)
Max. suction flow
[L/min(ANR)]
Air consumption
[L/min(ANR)]
ZL11.210057
ZL3M1.9300※1150
ZL3H1.5300※1135
ZL6M1.9×2600※1300
ZL6H1.5×2600※1270

Go Top

平远县| 冕宁县| 凤山县| 隆昌县| 克什克腾旗| 婺源县| 东方市| 东源县| 平和县| 黑河市| 天台县| 宝坻区| 盐山县| 揭阳市| 仙游县| 兴海县| 柳林县| 齐河县| 瓦房店市| 黄冈市| 济宁市| 保德县| 凉城县| 桐梓县| 崇州市| 常熟市| 福清市| 新和县| 简阳市| 长阳| 阜城县| 邓州市| 祥云县| 响水县| 常熟市| 襄垣县| 常宁市| 泉州市| 申扎县| 咸丰县| 九台市|