Product Information ?
WEB Catalog
IN_PROD_346
? Industrial Device Communication Equipment/Wireless System
? Industrial Device Communication Equipment: IO-Link Compatible Products
Industrial Device Communication Equipment: IO-Link Compatible Products
Serial Transmission System EX260
-
For Output
?The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
?IP67
?RJ45 communication connectors (X205)
?Related Products
?IO-Link Master
Safety Instructions 3/4/5 Port Solenoid Valves/Precautions Fieldbus System Precautions
Industrial IoT Cybersecurity Glossary of Fieldbus Terms Series Variations/Applicable Valve Series Safety over Fieldbus with PROFIsafe Green Procurement (RoHS) IO-Link Master
Industrial IoT Cybersecurity Glossary of Fieldbus Terms Series Variations/Applicable Valve Series Safety over Fieldbus with PROFIsafe Green Procurement (RoHS) IO-Link Master
Series | Enclosure | Communication protocol? | Applicable valve |
---|---|---|---|
EX260 | IP67 | DeviceNet? PROFIBUS DP CC-Link EtherCAT PROFINET EtherNet/IP? Ethernet POWERLINK IO-Link (Only available for SY, JSY, VQC communication connectors) PROFIsafe (Only available for SY, JSY, VQC communication connectors) | SY3000,5000,7000 (Plug-in) JSY1000,3000,5000 (Plug-in) VQC1000,2000,4000,5000 SV1000,2000,3000 S0700(IP40) |
IO-Link Master EX600-GILB-X60
-
?IO-Link version V1.1
?Process data length 32-byte input/32-byte output (per port)
?IO-Link port type Class A
?IO-Link Devices
Safety Instructions 3/4/5 Port Solenoid Valves/Precautions
Series Variations/Applicable Valve Series Green Procurement (RoHS)
Series Variations/Applicable Valve Series Green Procurement (RoHS)
Series | Number of ports | PLC communication protocol |
---|---|---|
EX600-GILB-X60 | 4 ports | CC-Link IE Field |
Serial Transmission System EX600
-
For Input/Output
?The applicable protocols differ depending on the series.
For details, refer to the catalog of each series.
?IO-Link Devices
? The EX600-SPN1/SPN2 series will be discontinued in October 2023.
Please select the EX600-SPN3/SPN4 series.
Safety Instructions 3/4/5 Port Solenoid Valves/Precautions Fieldbus System Precautions
Industrial IoT Cybersecurity Glossary of Fieldbus Terms Series Variations/Applicable Valve Series
Green Procurement (RoHS)
Industrial IoT Cybersecurity Glossary of Fieldbus Terms Series Variations/Applicable Valve Series
Green Procurement (RoHS)
Series | Enclosure | Communication protocol? | Applicable valve |
---|---|---|---|
EX600 | IP67 | PROFIBUS DP DeviceNet? CC-Link EtherNet/IP? EtherNet/IP? (IO-Link unit compatible) EtherCAT EtherCAT (IO-Link unit compatible) PROFINET PROFINET (IO-Link unit compatible) MRP (PROFINET) (Made to order) Ethernet POWERLINK (Made to order) Modbus TCP (Made to order) CC-Link IE Field (Made to order) EtherNet/IP? (IO-Link master compatible) (Made to order) | SY3000,5000,7000 (Plug-in) JSY1000, 3000, 5000 SV1000,2000,3000 VQC1000,2000,4000,5000 S0700(IP40) |
Wireless System EXW1/EX600-W
-
?Noise resistance
Uses the 2.4 GHz ISM frequency band
Frequency hopping: Every 2 ms (Fastest)
?Communication cables not required
Reduced wiring work, space, and cost
Minimized disconnection risk
?Provides communication stability in FA environments
?Compact and lightweight (EXW1)
Volume: Approx. 81% reduction, Weight: Approx. 76% reduction
?Modular connection is possible. (EX600-W)
?IO-Link Master
Safety Instructions 3/4/5 Port Solenoid Valves/Precautions Fieldbus System Precautions
Industrial IoT Cybersecurity Glossary of Fieldbus Terms Green Procurement (RoHS)
Industrial IoT Cybersecurity Glossary of Fieldbus Terms Green Procurement (RoHS)
Series | Enclosure | Communication protocol | Applicable valve |
---|---|---|---|
EXW1 | IP20/IP67 | DeviceNet? CC-Link EtherNet/IP? EtherCAT? PROFINET OPC UA | JSY1000, 3000, 5000 |
EX600-W | IP67 equivalent | EtherNet/IP? PROFINET | SY3000,5000,7000(Plug-in) SV1000,2000,3000 S0700(IP40) VQC1000,2000,4000,5000 |
Wireless System Compact Remote EX600-W
-
?Applicable to existing wireless systems
?Compact, Lightweight
Area: Approx. 61% reduction? (59.8 cm2 ← 155 cm2)
Volume: Approx. 86% reduction? (159 cm3 ← 1,139 cm3)
Weight: Approx. 87% reduction? (130 g ← 965 g)
? For the e-CON type
(Compared with the existing remote, M8 connector/digital 8 inputs specification)
?Variations
e-CON type, Grommet type, IO-Link device compatible
?Wireless System Base
?IO-Link Devices
Series | Enclosure | Communication protocol | Radio wave type |
---|---|---|---|
EX600-W | e-CON type: IP20 Grommet type: IP67 IO-Link device compatible: IP67 | SMC original protocol | Frequency Hopping Spread Spectrum (FHSS) |
Step Motor Controller JXCL1
-
?IO-Link version V1.1
?Process data length 14-byte input/22-byte output
?Transmission speed COM3 (230.4 kbps)
?Minimum cycle time 2.4 ms
?IO-Link port type Class A
?Click here for Applicable electric actuators
?IO-Link Master
Safety Instructions Electric Actuators/Precautions Features
Series Variations Simplified Selection Flow Chart Green Procurement (RoHS) IO-Link Master
Series Variations Simplified Selection Flow Chart Green Procurement (RoHS) IO-Link Master
Series | Number of axes | Compatible motor |
---|---|---|
JXCL1 | 1 axis | Step motor (Servo/24 VDC) |
Electro-Pneumatic Regulator ITV
-
?Stepless control of air pressure in proportion to electrical signals
?Sensitivity: 0.2 kPa (100 kPa specification)
?Linearity: ±1% or less (F.S.)
?Hysteresis: 0.5% or less (F.S.)
?Communication: CC-Link, DeviceNet?, PROFIBUS DP, RS-232C, IO-Link
?IO-Link Master
Safety Instructions F.R.L. Units/Precautions Series Variations/Pressure Control Equipment
Green Procurement (RoHS) IO-Link Master Electro-Pneumatic Regulator Application Examples
Green Procurement (RoHS) IO-Link Master Electro-Pneumatic Regulator Application Examples
Series | Port size | Set pressure (MPa) |
---|---|---|
ITV0000 | Built-in One-touch fitting φ4,φ5/32 | 0.001 to 0.1 0.001 to 0.5 0.001 to 0.9 |
ITV1000 | 1/8,1/4 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
ITV2000 | 1/4,3/8 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
ITV3000 | 1/4,3/8,1/2 | 0.005 to 0.1 0.005 to 0.5 0.005 to 0.9 |
Ionizer / Bar Type IZS51
-
?High speed static neutralization: Fastest time 0.1 s
?Space saving: Height 70 mm x Width 28 mm
Compact and flat body
Can be mounted in narrow spaces
?Supports the IO-Link communication protocol
?Low maintenance cartridge
Concentrating the air (for reducing emitter contamination)
around the emitter and the assisting air (for ion transfer)
Reduces dirt on the emitter, compared with the existing model
?Valve unit option
For reduction in air consumption by stopping air purge during stand-by
mode
?IO-Link Devices
Variations/Application Examples Antistatic Equipment Glossary
Safety Instructions Green Procurement (RoHS)
Safety Instructions Green Procurement (RoHS)
Series | Ion generation method | Offset voltage (Ion balance) | Function |
---|---|---|---|
IZS51 | Corona discharge type | Within ±30 V | Auto ion balance Maintenance detection High voltage abnormality detection Ion generation stop input |
Separate Controller Ionizer/Bar Type/Nozzle Type IZT40/41/42/43
-
?The controller and high-voltage power supply module can be mounted
separately.
?Space saving: Height 37 mm x Width 30 mm (Bar type)
Thickness 16 mm x Width 53 mm x Height 32 mm (Nozzle type)
?One controller can control a maximum of 4 ionizers.
?Potential amplitude: 25 V or less
?Rapid static neutralization: Fastest time of 0.1 s
?3 types of emitter cartridges
High speed static neutralization cartridge
Energy saving static neutralization cartridge
Energy saving high-efficiency cartridge
?Static neutralization is possible even when air is not being supplied.
?IO-Link Compatible
?IO-Link Devices
Variations/Application Examples Antistatic Equipment Glossary
Safety Instructions Green Procurement (RoHS)
Safety Instructions Green Procurement (RoHS)
Series | Type | Ion generation method | Offset voltage (Ion balance) |
---|---|---|---|
IZT42(-L) Bar type | Dual AC Type | Corona discharge type | Within ±30 V |
IZT41(-L) Bar type | AC Type | Corona discharge type | Within ±30 V |
IZT40 Bar type | Standard Type | Corona discharge type | Within ±30 V |
IZT43(-L) Nozzle type | AC Type | Corona discharge type | Within ±30 V |
3-Screen Display High-Precision Digital Pressure Switch
ZSE20□(F)/ISE20□
-
?Visualization of settings
?Simple 3-step setting
?Easy screen switching
It is possible to change the settings while checking the measured value.
?Delay time:1.5 ms or less
?Current consumption: 25 mA or less
?IO-Link compatible
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Output type | Type | Rated pressure range | Enclosure | Applicable fluid |
---|---|---|---|---|---|
ZSE20(F) ISE20 | 1 output | Compound pressure Vacuum pressure Positive pressure | ?100.0 to 100.0 kPa 0.0 to ?101.0 kPa ?0.100 to 1.000 MPa | IP40 | Air |
ZSE20A(F) ISE20A | 2 outputs Analog output (Voltage/Current) | Compound pressure Vacuum pressure Positive pressure | ?100.0 to 100.0 kPa 0.0 to ?101.0 kPa ?0.100 to 1.000 MPa | IP40 | Air |
ZSE20AF-X576 to 580 (Made to Order) | 2 outputs Analog output (Voltage/Current) | Compound pressure | ?500 to 500Pa ?1.000 to 1.000kPa ?2.00 to 2.00kPa ?5.00 to 5.00kPa ?10.00 to 10.00kPa | IP40 | Air |
ZSE20B(F)-(L) ISE20B-(L) | 2 outputs Analog output (Voltage/Current) IO-Link/Switch: 1 output | Compound pressure Vacuum pressure Positive pressure | ?100.0 to 100.0 kPa 0.0 to ?101.0 kPa ?0.100 to 1.000 MPa | IP65 | Air |
ZSE20C(F)-(L) ISE20C(H)-(L) | 2 outputs Analog output (Voltage/Current) IO-Link/Switch: 1 output | Compound pressure Vacuum pressure Positive pressure | ?100.0 to 100.0 kPa 0.0 to ?101.0 kPa ?0.100 to 1.000 MPa ?0.100 to 2.000 MPa | IP65 | General fluids |
3-Screen Display High-Precision Digital Pressure Switch
ISE7□/7□G/79S
-
?It is possible to change the settings while checking the measured value.
?IO-Link
?Angled display
Good visibility from various mounting positions
?Rotating display
Display can rotate 336 degrees after installation
?Applicable fluid:Air, Non-corrosive gas, Non-flammable gas (ISE70/71)
:Liquid or gas that will not corrode materials of parts
in contact with fluid (ISE7□G/79S)
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS)
Series | Type | Rated pressure range |
---|---|---|
ISE70 | Positive pressure (For air) | 0 to 1MPa |
ISE71 | Positive pressure (For air) | 0 to 1.6MPa |
ISE70G | Positive pressure (For general fluids) | 0 to 1MPa |
ISE75G | Positive pressure (For general fluids) | 0 to 2MPa |
ISE76G | Positive pressure (For general fluids) | 0 to 5MPa |
ISE77G | Positive pressure (For general fluids) | 0 to 10MPa |
ISE78G | Positive pressure (For general fluids) | 0 to 16MPa |
ISE79S | Positive pressure (For general fluids) | 0 to 50MPa |
3-Screen Display Digital Gap Checker/IO-Link Compatible ISA3-L
-
?Monitoring the placement condition of the workpiece Indicates failure/abnormality
?Double sensor providing improved preventive and predictive maintenance (IoT) based on IO-Link
Process data provides Displayed value, Outlet pressure, and Supply pressure value.
?NPN/PNP switch function
?3-screen display (Setting)
?Window comparator type
?Zero cut-off range can be changed.
?IO-Link Master
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS) IO-Link Master
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS) IO-Link Master
Series | Rated distance range | Piping specifications: Supply side | Piping specifications: Detection side |
---|---|---|---|
ISA3-F□L | 0.01 to 0.03 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
ISA3-G□L | 0.02 to 0.15 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
ISA3-H□L | 0.05 to 0.30 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
3-Screen Display Multi-channel Digital Sensor Monitor PSE200A
-
?Up to 4 pressure sensors can be connected!
Centralized control saves installation space.
A single monitor various applications
?It is possible to change the settings while checking the measured value.
?IO-Link compatible
?IO-Link Master
Safety Instructions Pressure Switches/Flow Switches/Precautions
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS) IO-Link Master
Pressure Switch Series Variations/Application Example Glossary of Terms/Technical Information
Green Procurement (RoHS) IO-Link Master
Series | Set pressure range | Applicable pressure sensors |
---|---|---|
PSE200A | ?0.2 to 2.1 kPa 10 to ?105 kPa ?105 to 105 kPa ?10 to 105 kPa ?50 to 525 kPa ?0.105 to 1.05 MPa ?0.105 to 2.1 MPa ?0.25 to 5.25 MPa ?0.5 to 10.5 MPa | PSE550 PSE531/PSE541/PSE561 PSE533/PSE543/PSE563/PSE573 PSE532 PSE564/PSE574 PSE530/PSE540/PSE560/PSE570 PSE575 PSE576 PSE577 |
3-Color Display Digital Flow Switch PF2MC7□(-L)
-
?Dry air, N2
?3-color/3-screen display
?A wide range of flow measurement is possible with 1 product.
Flow ratio 100:1, Smallest settable increment: 1 L/min
?Grease-free
?IO-Link compatible
?IO-Link Master
Safety Instructions Pressure Switches/Flow Switches/Precautions Flow Switch Series Variations
Green Procurement (RoHS) IO-Link Master
Green Procurement (RoHS) IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF2MC | 5 to 500 10 to 1000 20 to 2000 |
2-Color Display Digital Flow Switch PF2M7(-L)
-
?3-Screen Display Digital Flow Monitor (Dedicated for the PF2M7) [New]
Allows for the monitoring of remote lines PFGM302 Series
?Dry air, N2, Ar, CO2
?A wide range of flow measurement is possible with 1 product.
Flow ratio: 100:1, Smallest settable increment: 0.01 L/min
?Improved resistance to moisture and foreign matter
?Compact, Lightweight
Weight: 27.3% lighter (55 g → 40 g)
?Low current consumption: 35 mA or less
?Grease-free
?IO-Link compatible
?IO-Link Master
Safety Instructions Pressure Switches/Flow Switches/Precautions Flow Switch Series Variations
Green Procurement (RoHS) IO-Link Master
Green Procurement (RoHS) IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF2M7 | 0.01 to 1 (0.01 to 0.5) 0.02 to 2 (0.02 to 1) 0.05 to 5 (0.05 to 2.5) 0.1 to 10 (0.1 to 5) 0.3 to 25 (0.3 to 12.5) 0.5 to 50 (0.5 to 25) 1 to 100 (1 to 50) 2 to 200 (2 to 100) ( ): For CO2 |
3-Color Display Digital Flow Switch for Water PF3W-Z/L
-
?Applicable fluid: Water, Ethylene glycol aqueous solution
?Lightweight: Max. 53% reduction (40 L/min, With temperature sensor)
?IO-Link compatible
?3-color/2-screen display
?Compatible with the temperature sensor & flow adjustment valve
?Fluid temperature: 0 to 90℃
?Compatible with the PFG200 series 3-screen display 4-channel flow
monitor
?IO-Link Master
Safety Instructions Pressure Switches/Flow Switches/Precautions Flow Switch Series Variations
Green Procurement (RoHS) IO-Link Master
Green Procurement (RoHS) IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF3W-Z | 0.5 to 4 2 to 16 5 to 40 10 to 100 |
PF3W-L (IO-Link compatible) | 0.5 to 4 2 to 16 5 to 40 10 to 100 50 to 250 |
Digital Flow Switch Manifold for Water PF3WB/C/S/R
-
?Applicable fluid: Water, Ethylene glycol aqueous solution
?Space saving
Footprint Max. 85% reduction
Weight Max. 65% reduction
?Needs no piping: Work-hour for installation reduced by up to 45%
?IO-Link compatible
?3-color/2-screen display
?Fluid temperature: 0 to 90℃
?IO-Link Master
Safety Instructions Pressure Switches/Flow Switches/Precautions Flow Switch Series Variations
Green Procurement (RoHS) IO-Link Master
Green Procurement (RoHS) IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF3WB Integrated type (Basic type) | 0.5 to 4 2 to 16 5 to 40 |
PF3WC Integrated type (Straight type) | 0.5 to 4 2 to 16 5 to 40 |
PF3WS Remote type (Supply type) | 0.5 to 4 2 to 16 5 to 40 |
PF3WR Remote type (Return type) | 0.5 to 4 2 to 16 5 to 40 |
3-Color Display Digital Flow Switch for Large Flow PF3A□H(-L)
-
?Applicable fluid: Air, N2
?Flow range: Max. 12000 L/min
?Flow ratio 100:1
A wide range of flow measurement is possible with 1 product.
?Improved drainage and resistance to foreign matter
?Pressure loss: 75% reduction (20 kPa → 5 kPa)
?Through bore construction
?IO-Link compatible
?Can be connected to the air combination (Modular type)
?A 4-screen display digital flow switch with pressure/temperature sensor
(modular type) is available.
Simultaneous measurement of the (accumulated) flow rate, pressure, and temperature is possible.
?IO-Link Master
Safety Instructions Pressure Switches/Flow Switches/Precautions
Green Procurement (RoHS) IO-Link Master
Green Procurement (RoHS) IO-Link Master
Series | Rated flow range (L/min) |
---|---|
PF3A7□H | 10 to 1000 20 to 2000 30 to 3000 60 to 6000 120 to 12000 |
Digital Flow Switch for Water PF3W7□-X445
-
?IO-Link version V1.1
?Process data length 6-byte input
?Transmission speed COM2 (38.4 kbps)
?Minimum cycle time 3.5 ms
?IO-Link port type Class A
?IO-Link Master
Safety Instructions Pressure Switches/Flow Switches/Precautions Flow Switch Series Variations
Green Procurement (RoHS) IO-Link Master
Green Procurement (RoHS) IO-Link Master
Series | Applicable fluid | Rated flow range |
---|---|---|
PF3W704-X445 | Water | 0.5 to 4 L/min |
PF3W720-X445 | Water | 2 to 16 L/min |
PF3W740-X445 | Water | 5 to 40 L/min |
Actuator Position Sensor D-MP□
-
?Actuator stroke position is output with an analog signal.
?Repeatability: 0.1 mm
?Analog output
?4 measurement ranges
?Switch output
?IO-Link compatible
Series | Measuring range |
---|---|
D-MP025 | 25 mm±1 mm |
D-MP050 | 50 mm±1 mm |
D-MP100 | 100 mm±1 mm |
D-MP200 | 200 mm±1 mm |
Vacuum Manifold for Fieldbus System ZKJ
-
?Vacuum pads and actuator driving can be controlled with a single
manifold [New]
?Positive pressure unit [New]
5-port solenoid valve
?Vacuum unit
Energy saving ejector Air consumption: 92% reduction
?Fieldbus compatible
Space saving: Requires no separate input/output units
Reduced wiring time
Compatible protocols: PROFINET, IO-Link, EtherNet/IP, EtherCAT
?Exhaust sealing function
Quick workpiece release
?4 stations/8 stations/12 stations/16 stations manifold compatible
Safety Instructions Vacuum Equipment/Precautions Series Variations/Model Selection
Green Procurement (RoHS)
Green Procurement (RoHS)
Ejector series | Nozzle diameter (mm) | Max. suction flow [L/min(ANR)] | Air consumption [L/min(ANR)] |
---|---|---|---|
ZKJ07 | 0.7 | 31 | 26 |
ZKJ10 | 1.0 | 53 | 48 |
ZKJ12 | 1.2 | 63 | 68 |
ZKJ15 | 1.5 | 74 | 102 |
64-station Compatible Manifold Plug-in Compact 5-Port Solenoid Valve JSY3000-L
-
?Valve stations/Number of outputs: For 4 to 64 stations? /128 points
? Stations are only available in multiples of 4.
?Space saving, Reduced number of SI units, Reduced wiring and wiring
work
Safety Instructions 3/4/5 Port Solenoid Valves/Precautions Selection/Technical Data
Green Procurement (RoHS)
Green Procurement (RoHS)
Series | Flow rate characteristics 4/2 → 3/5 (A/B → E) C [dm3/(s·bar)] | Flow rate characteristics 4/2 → 3/5 (A/B → E) b | Applicable cylinder size | Power consumption (W) |
---|---|---|---|---|
JSY3000-L | 2.77 | 0.27 | φ50 | 0.4 (Standard) 0.1 (With power-saving circuit) |
IO-Link Compatible 2 in 1 Auto Switch D-MH2□
-
?Outputs process data according to the actuator stroke position
?A single switch can discriminate between max. 3 position points.
?Discriminable resolution: ±0.1 mm ? Within the high-resolution range
?Detection position setting can be done away from the actuator.
?Process data output (–1000 to 1000)
Can also be used with the 2 in 1 auto switch single unit if there is
an IO-Link master
Series | Type | Number of set points | Output type |
---|---|---|---|
D-MH2□ | IO-Link compatible 2 in 1 auto switch | 2 points 3 points | NPN output PNP output |
Valve Manifold Integrated with Ejector System JSY1000-E
-
?Spacer type ejector with additional high-noise reduction silencer [New]
?A vacuum release flow adjustment unit has been added.
?Compact all-in-one manifold
The devices have been integrated into one for applications in which an
actuator and vacuum suction are used together.
?EtherCAT?,IO-Link [New],PROFINET? [New] compatible
?Wiring/piping saving through use of all-in-one manifold
?Installation area: 64% reduction
?Weight: 42% reduction
?Energy saving function
CO2 emissions (Air consumption): 90% reduction
?IO-Link Master
Safety Instructions 3/4/5 Port Solenoid Valves/Precautions Selection/Technical Data
Green Procurement (RoHS)
Green Procurement (RoHS)
Series | Flow rate characteristics 4/2→3/5 (A/B→E) C [dm3/(s?bar)] | Flow rate characteristics 4/2→3/5 (A/B→E) b | Applicable cylinder size | Power consumption (W) |
---|---|---|---|---|
JSY1000-E | 0.91 | 0.48 | φ40 | 0.2 (With power-saving circuit) |