Product Information ?
WEB Catalog
IN_PROD_346
? Temperature Control Equipment
? Chiller Compliant Regulations
Chiller Compliant Regulations
Non F-Gas (CO2 Refrigerant) Refrigerated Thermo-chiller HRZC
-
?Non F-Gas
?Uses a CO2 refrigerant
?Greatly reduced GWP
?GWP = 1 Compliant with each country’s refrigerant regulations
EU refrigerant regulations: GWP150 or more
US refrigerant regulations: GWP700 or more
California, US refrigerant regulations: GWP750 or more
? “GWP” indicates the global warming potential. The values are based on
the IPCC AR4.
?Air transport possible
?Eliminates the need to pay for F-Gas recovery & disposal
?Eliminates the need for periodic inspections based on the Fluorocarbon
Emissions Control Act (Japan)
Safety Instructions Temperature Control Equipment/Precautions Features/Series Variations
Technical Data Temperature Control Equipment Warranty Green Procurement (RoHS)
Technical Data Temperature Control Equipment Warranty Green Procurement (RoHS)
Series | Set temperature range | Cooling capacity | Temperature stability | Cooling method | Circulating fluid |
---|---|---|---|---|---|
HRZC | ?20 to 90℃ | 10 kW | ±0.1℃ | Water-cooled refrigeration | Fluorinated fluids 60% ethylene glycol aqueous solution Deionized water/Tap water |
Thermo-chillers for the Semiconductor Industry INR-495-042/INR-495-043
-
?Non F-Gas (CO2 refrigerant)
?GWP: 1 (Natural refrigerant)
?EU refrigerant regulations: GWP150 or less?
?US refrigerant regulations: GWP700 or less?
?California, US refrigerant regulations: GWP750 or less
?As of December 2023
?Air transport possible
No air transport restrictions for non-toxic and non-flammable?
refrigerants
?A1 (ASHRAE34 standard)
?No F-Gas management required
Eliminates the need for periodic inspections based on the Fluorocarbon
Emissions Control Act (Japan)
?No F-Gas recovery & disposal costs
Series | Set temperature range | Cooling capacity | Temperature stability | Cooling method | Circulating fluid |
---|---|---|---|---|---|
INR-495-042 INR-495-043 | -20 to 70 | 8.5 kW | ±1.0℃ | Water-cooled refrigeration | Fluorinated fluid |
Low GWP Refrigerant Chiller/Refrigerated Thermo-chiller HRZF
-
· Low GWP refrigerant chiller
GWP:146? ? Regulation (EU) 2024/573, AIM Act 40 CFR Part 84
EU refrigerant regulations: GWP150 or more
US refrigerant regulations: GWP700 or more
California, US refrigerant regulations: GWP750 or more
· Environmentally friendly R454C as refrigerant (Not available for air
transport)
· More effective energy-saving is achieved through use of a DC inverter
compressor and an inverter pump.
Safety Instructions Temperature Control Equipment/Precautions Features/Series Variations
Technical Data Temperature Control Equipment Warranty Green Procurement (RoHS)
Technical Data Temperature Control Equipment Warranty Green Procurement (RoHS)
Series | Set temperature range | Cooling capacity | Temperature stability | Cooling method | Circulating fluid |
---|---|---|---|---|---|
HRZF010 | -20?90℃ | 10kW | ±0.1℃ | Water-cooled refrigeration | Fluorinated fluids, 60% ethylene glycol aqueous solution |
Low GWP Refrigerant Chiller Thermo-chiller Standard Type HRSF150/200
-
?Low GWP Refrigerant Chiller
GWP: 146? ? Regulation (EU) 2024/573, AIM Act 40 CFR
Part 84
EU refrigerant regulations: GWP150 or more
US refrigerant regulations: GWP700 or more
California, US refrigerant regulations: GWP750 or more
?Environmentally friendly R454C as refrigerant (Not available for air
transport)
?No heater is required, as the circulating fluid is heated using only the heat
exhausted by the refrigerating circuit.
?Compatible with power supplies in Europe, Asia, Oceania, and North,
Central, and South America
?3-phase 400 VAC Low-noise design 70 dB(A)
?Outdoor installation IPX4
Safety Instructions Temperature Control Equipment/Precautions Features/Series Variations
Technical Data Can be used in a wide range of applications!
Temperature Control Equipment Warranty Green Procurement (RoHS)
Technical Data Can be used in a wide range of applications!
Temperature Control Equipment Warranty Green Procurement (RoHS)
Series | Set temperature range | Cooling capacity | Temperature stability | Cooling method | Circulating fluid |
---|---|---|---|---|---|
HRSF150 HRSF200 | 5 to 35℃ | 15.7kW 20.5kW (Air-cooled) 20.6kW (Water-cooled) | ±1.0℃ | Air-cooled refrigeration Water-cooled refrigeration | Tap water 15 to 40% Ethylene glycol aqueous solution Deionized water |